SR EN 14789:2006
Stationary source emissions - Determination of volume concentration of oxygen (O2) - Reference method - Paramagnetism
This European Standard describes the paramagnetic method, including the sampling and the gas conditioning system, to determine the oxygen concentrations in flue gases emitted to the atmosphere from ducts and stacks. This European Standard is the Standard Reference Method (SRM) for periodic monitoring and for the calibration or control of Automatic Measuring Systems (AMS) permanently installed on a stack, for regulatory purposes or other purposes. To be used as the SRM, the user shall demonstrate that the performance characteristics of the method are better than the performance criteria defined in this European Standard and that the overall uncertainty of the method is less than ± 6,0 percent of the measured concentration. NOTE When paramagnetism is the measurement principle used for AMS, reference should be made to EN 14181 and other relevant standards provided by CEN/TC 264. An alternative method to this SRM may be used provided that the user can demonstrate equivalence according to the Technical Specification CEN/TS 14793, to the satisfaction of his national accreditation bo
Status :
Withdrawn
Approval date : 5/30/2006
Publish date : 6/1/2006
Withdrawal date : 6/30/2017
Number of pages : 40
ICS : 13.040.40 Stationary source emissions
Technical Committee : 53 - Air quality
- Normative reference SR ENV 13005:2003
- Normative reference SR EN ISO 14956:2003
- Replaced by SR EN 14789:2017