SR EN ISO 9614-3:2010

Acoustics - Determination of sound power levels of noise sources using sound intensity - Part 3: Precision method for measurement by scanning (ISO 9614-3:2002)

ISO 9614-3:2002 specifies a method for measuring the component of sound intensity normal to a measurement surface which is chosen so as to enclose the sound source(s) of which the sound power level is to be determined. Surface integration of the intensity component normal to the measurement surface is approximated by subdividing the measurement surface into contiguous partial surfaces, and scanning the intensity probe over each partial surface along a continuous path which covers the extent of the partial surface. The measurement instrument determines the averaged normal intensity component and averaged squared sound pressure over the duration of each scan. The scanning operation can be performed either manually or by means of a mechanical system. The octave band or band-limited weighted sound power level is calculated from the measured one-third-octave- band values. The method is applicable to any source for which a physically stationary measurement surface can be defined, and on which the sound generated by the source under test and by other significant extraneous sources

45.30

Status : Valid
Approval date : 1/29/2010
Publish date : 1/31/2010
Number of pages : 46
ICS : 17.140.01 Acoustic measurements and noise abatement in gerneral
Technical Committee : 274 - Human protection against noise and mechanical vibration

Relations with other standards: