SR EN 60079-35-1+AC:2012

Explosive atmospheres -- Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion

IEC 60079-35-1:2011 specifies requirements for the construction, testing and marking of caplights, including caplights with a point of connection for other equipment, for use in mines susceptible to firedamp (Group I - electrical equipment for explosive gas atmospheres as defined in IEC 60079-0). It deals only with the risk of the caplight becoming a source of ignition. The requirements for performance are in IEC 60079-35-2. This standard supplements and modifies the general requirements of IEC 60079-0 except as indicated in Table 1. This first edition cancels and replaces the second edition of IEC 62013-1, published in 2005, and constitutes a full technical revision. The main technical differences with respect to the previious edition are: - the introduction of a means to achieve an equipment protection level (EPL) of Ma; - the introduction of a single clause relating to equipment construction replacing individual specific clauses for the headpiece, battery, cable and external charging contacts; - the deletion of statements relating to surface temperature, the rewording of

35.74

Status : Valid
Approval date : 3/30/2012
Number of pages : 28
ICS : 29.260.20 Electrical apparatus for explosive atmospheres
Technical Committee : 137 - Electrical apparatus for explosive atmospheres

Relations with other standards: