SR CEN/TS 1187:2012
Test methods for external fire exposure to roofs
This Technical Specification specifies four methods for determining the performance of roofs to external fire exposure. The four methods assess the performance of roofs under the following conditions: a) test 1 - with burning brands; b) test 2 - with burning brands and wind; c) test 3 - with burning brands, wind and supplementary radiant heat; d) test 4 - with two stages incorporating burning brands, wind and supplementary radiant heat. The tests assess the fire spread across the external surface of the roof, the fire spread within the roof (tests 1, 2 and 3), the fire penetration (tests 1, 3 and 4) and the production of flaming droplets or debris falling from the underside of the roof or from the exposed surface (tests 1, 3 and 4). Tests 2 and 3 are not applicable to geometrically irregular roofs or roof mounted appliances, e.g. ventilators and roof lights. NOTE The four tests listed above do not imply any ranking order. Each test stands on its own without the possibility to substitute or exchange one for another.
Status :
Valid
Approval date : 3/30/2012
Number of pages : 64
ICS : 13.220.50 Fire-resistance of building materials and elements,91.060.20 Roofs
Technical Committee : 217 - Fire safety in buildings
- Replaces SR ENV 1187:2003
- Normative reference SR EN 13238:2010
- Normative reference SR EN 13501-1+A1:2010
- Normative reference SR EN 13501-5+A1:2010
- Normative reference SR EN ISO 13943:2011
RO