SR EN 60601-1-2:2016
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60601-1-2:2014 applies to the basic safety and essential performance of Medical Equipment (ME) equipment and ME systems in the presence of electromagnetic disturbances and to electromagnetic disturbances emitted by me equipment and me systems. This collateral standard to IEC 60601-1 specifies general requirements and tests for basic safety and essential performance with regard to electromagnetic disturbances and for electromagnetic emissions of ME equipment and ME systems. They are in addition to the requirements of the general standard IEC 60601-1 and serve as the basis for particular standards. This fourth edition cancels and replaces the third edition of IEC 60601-1-2, and constitutes a technical revision. The most significant changes with respect to the previous edition include the following modifications: - specification of immunity test levels according to the environments of intended use, categorized according to locations that are harmonized with IEC 60601-1-11: the professional healthcare facility environment, the home healthcare environment and special environme
Status :
Valid
Approval date : 2/29/2016
Number of pages : 110
ICS : 11.040.01 Medical equipmet in general,33.100.10 Emission,33.100.20 Immunity
Technical Committee : 22 - Electrical equipment in medical practice
- Replaces SR EN 60601-1-2:2007/AC:2014
- Replaces SR EN 60601-1-2:2007
- Normative reference SR EN 60601-1:2007
- Normative reference SR EN 60601-1:2007/AC:2015
- Normative reference SR EN 60601-1:2007/A1:2014
- Normative reference SR EN 60601-1:2007/A12:2015
- Normative reference SR EN 60601-1-8:2007
- Normative reference SR EN 60601-1-8:2007/AC:2014
- Normative reference SR EN 60601-1-8:2007/A1:2013
- Normative reference SR EN 60601-1-11:2011
- Normative reference SR EN 60601-1-12:2015
- Normative reference SR EN 60601-2-3:2015
- Normative reference SR EN 61000-3-2:2006
- Normative reference SR EN 61000-3-2:2006/A1:2010
- Normative reference SR EN 61000-3-2:2006/A2:2010
- Normative reference SR EN 61000-3-3:2014
- Normative reference SR EN 61000-4-2:2009
- Normative reference SR EN 61000-4-3:2006
- Normative reference SR EN 61000-4-3:2006/A1:2008
- Normative reference SR EN 61000-4-3:2006/A2:2011
- Normative reference SR EN 61000-4-4:2013
- Normative reference SR EN 61000-4-5:2007
- Normative reference SR EN 61000-4-8:2010
- Normative reference SR EN 61000-4-11:2005
- Normative reference SR EN 55011:2010
- Normative reference SR EN 55014-1:2007
- Normative reference SR EN 55014-1:2007/A1:2009
- Normative reference SR EN 55014-1:2007/A2:2012
- Normative reference SR EN 55016-1-2:2005
- Normative reference SR EN 55016-1-2:2005/A1:2006
- Normative reference SR EN 55016-1-2:2005/A2:2007
- Normative reference SR EN 55032:2012
- Normative reference SR ISO 7137:2008
- Normative reference SR EN ISO 14971:2012
- Amended by SR EN 60601-1-2:2016/A1:2021
RO