SR EN ISO 16283-3:2016
Acoustics - Field measurement of sound insulation in buildings and of building elements - Part 3: Façade sound insulation (ISO 16283-3:2016)
ISO 16283-3:2016 specifies procedures to determine the airborne sound insulation of façade elements (element methods) and whole façades (global methods) using sound pressure measurements. These procedures are intended for room volumes in the range from 10 m3 to 250 m3 in the frequency range from 50 Hz to 5 000 Hz. The test results can be used to quantify, assess, and compare the airborne sound insulation in unfurnished or furnished rooms where the sound field can or cannot approximate to a diffuse field. The measured airborne sound insulation is frequency-dependent and can be converted into a single number quantity to characterize the acoustic performance using the rating procedures in ISO 717-1.
Status :
Valid
Approval date : 7/29/2016
Number of pages : 44
ICS : 91.060.10 Walls. Partitation. Facades,91.120.20 acoustics in building.Sound insulation
Technical Committee : 276 - Building acoustics
- Replaces SR EN ISO 140-14:2005
- Replaces SR EN ISO 140-5:2002
- Replaces SR EN ISO 140-14:2005/AC:2009
- Normative reference SR EN 61672-1:2014
- Normative reference SR EN 61260-1:2014
- Normative reference SR EN 61260-2:2016/A1:2018
- Normative reference SR EN ISO 18233:2006
- Normative reference SR EN ISO 3382-2:2008/AC:2009
- Normative reference SR EN ISO 12999-1:2014
- Normative reference SR EN 60942:2004
- Normative reference SR EN ISO 3382-2:2008
- Normative reference SR EN 61260-2:2016
- Normative reference SR EN 61183:2003
- Normative reference SR EN 61260-3:2016
- Normative reference SR EN ISO 717-1:2013