SR EN IEC 61000-4-11+AC:2020

Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase

<!-- NEW! -->IEC 61000-4-11:2020 is available as <a href="https://webstore.iec.ch/publication/66487">IEC 61000-4-11:2020 RLV</a> which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.</br></br>IEC 61000-4-11:2020 defines the immunity test methods and range of preferred test levels for electrical and electronic equipment connected to low-voltage power supply networks for voltage dips, short interruptions, and voltage variations. This document applies to electrical and electronic equipment having a rated input current not exceeding 16 A per phase, for connection to 50 Hz or 60 Hz AC networks. It does not apply to electrical and electronic equipment for connection to 400 Hz AC networks. Tests for these networks will be covered by future IEC documents. The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to voltage dips, short interruptions and voltage variations. NOTE 1 Voltage fluctuation immunity

61.25

Status : Valid
Approval date : 7/31/2020
Number of pages : 36
ICS : 33.100.20 Immunity
Technical Committee : 30 - Electromagnetic compatibility and radio interference

Relations with other standards: