SR EN ISO 1182:2020
Reaction to fire tests for products - Non-combustibility test (ISO 1182:2020)
This document specifies a test method for determining the non-combustibility performance, under specified conditions, of homogeneous products and substantial components of non-homogeneous products. Information on the precision of the test method is given in Annex A.
Status :
Valid
Approval date : 7/31/2020
Number of pages : 38
ICS : 13.220.50 Fire-resistance of building materials and elements
Technical Committee : 217 - Fire safety in buildings
- Replaces SR EN ISO 1182:2010
- Normative reference SR EN ISO 13943:2018
- Normative reference SR EN 60584-1:2014
- Normative reference SR EN 13238:2010