SR EN IEC 60216-5:2023

Electrical insulating materials - Thermal endurance properties - Part 5: Determination of relative temperature index (RTI) of an insulating material

IEC 60216-5:2022 specifies the experimental and calculation procedures to be used for deriving the relative temperature index of a material from experimental data obtained in accordance with the instructions of IEC 60216-1 and IEC 60216-2. The calculation procedures are supplementary to those of IEC 60216-3. Guidance is also given for assessment of thermal ageing after a single fixed time and temperature, without extrapolation. This edition includes the following significant technical changes with respect to the previous edition: <ol style="list-style-type:lower-alpha"> <li style="text-align:left">Annex C “Computer program” has been completely reworked;</li> <li style="text-align:left">in 3.1, the terms “ATE” and “RTE” were replaced by “ATI” and “RTI” to emphasize their reference to an electrical insulating material (EIM).</li> </ol> This standard is to be read in conjunction with IEC 60216-1:2013, IEC 60216-2:2005 and IEC 60216-3:2021.

55.93

Status : Valid
Approval date : 2/28/2023
Number of pages : 66
ICS : 19.020 Test conditions and procedures in general,29.020 Electrical engineering in general,29.035.01 Insulating materials in general
Technical Committee : 5 - Insulation materials and electrical insulation systems

Relations with other standards: