SR EN 50306-2:2003
Railway applications - Railway rolling stock cables having special fire performance - Thin wall -- Part 2: Single core cables
EN 50306-2 specifies requirements for, and constructions and dimensions of, single core cables, rated 300 V to earth, of the following type: Unscreened (0,5 mm2 to 2,5 mm2 single core) All cables have stranded tinned copper conductors and thin wall thickness, halogen-free insulation. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous operational life at 105 °C, and a maximum temperature for short-circuit conditions of 160 °C based on a duration of 5 seconds. NOTE 1 Where these single core cables are used as components of sheathed cables, the temperature for continuous operational life depends upon the type of sheath system used. Sheath systems for either 90 °C for 105 °C are defined in other parts of EN 50306. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cable
You must log in to add this product to favorites.
Status :
Withdrawn
Approval date : 6/30/2003
Publish date : 7/1/2003
Withdrawal date : 12/30/2022
Number of pages : 20
ICS : 13.220.20 Fire protection,45.060.01 Railway rolling stock in general
Technical Committee : 159 - Electric cables
- Normative reference SR EN 45545-1:2013
- Replaced by SR EN 50306-2:2020
RO