SR EN 777-1:2002

Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use - Part 1: System D, safety

This European Standard specifies the requirements and test methods for the construction, safety, classification and marking of non-domestic gas-fired overhead radiant tube heaters incorporated into a multi-burner system (referred to in the body of the text as the 'system') with each burner unit under the control of an automatic burner control system. This standard is applicable to Type B22 systems (see 4.3) intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means. This standard is not applicable to: - systems designed for use in domestic dwellings; - outdoor systems; - systems in which the heat input of an individual burner unit exceeds 120 kW (based on the net calorific value of the appropriate reference test gas); - systems having a draught diverter; - systems having fully pre-mixed gas and air burners in which: - either the gas and all the combustion air are brought together just before the level of the combustion zone; - or the pre-mixing of the gas and al

Status : Withdrawn
Approval date : 8/29/2002
Publish date : 8/30/2002
Withdrawal date : 8/31/2009
Number of pages : 78
ICS : 97.100.20 Gas heaters
Technical Committee : 225 - Central heating boilers

Relations with other standards: