This European Standard specifies procedures for establishing quality assurance levels (QALs) for automated measuring systems (AMS) installed on industrial plants for the determination of the flue gas components and other flue gas parameters. This European Standard specifies procedures for establishing quality assurance levels (QALs) for automated measuring systems (AMS) installed on industrial plants for the determination of the flue gas components and other flue gas parameters. This standard specifies: - a procedure (QAL 2) to calibrate the AMS and determine the variability of the measured values obtained by an automated measurement system which is suitable for the validation of an AMS following its installation; - a procedure (QAL 3) to maintain and demonstrate the required quality of the measurement results during the normal operation of an AMS, by checking that the zero and span characteristics are consistent with those determined during QAL 1; - a procedure for the annual surveillance tests (AST) of the AMS in order to evaluate (i) that it functions correctly and its p
Status :
Withdrawn
Approval date : 11/25/2004
Publish date : 11/26/2004
Withdrawal date : 4/30/2015
Number of pages : 60
ICS : 13.040.40 Stationary source emissions
Technical Committee : 53 - Air quality
- Normative reference SR EN ISO 14956:2003
- Normative reference SR EN ISO/CEI 17025:2005
- Replaced by SR EN 14181:2015