SR EN 13941+A1:2010
Design and installation of preinsulated bonded pipe systems for district heating
This European Standard specifies rules for design, calculation and installation for preinsulated bonded pipe systems for buried hot water distribution and transmission networks (cf. Figure 2) with pipe assemblies in accordance with EN 253, for continuous operation with hot water at various temperatures up to 120oC and occasionally with peak temperatures up to 140oC and maximum internal pressure 25 bar (overpressure). Application rule: For larger pipe dimensions and pressures below 25 bar wall thickness bigger than specified in EN 253 can be required for straight pipes, bends and tees. The principles of the standard can be applied to preinsulated pipe systems with pressures higher than 25 bar, provided that special attention is paid to the effects of pressure. Adjacent pipes belonging to the network (e.g. pipes in ducts, valve chambers, road crossings above ground etc.) can be designed and installed according to this standard. The standard assumes use of treated water, which by softening, demineralisation, deaeration, adding of chemicals, or otherwise has been treated to preven
Status :
Withdrawn
Approval date : 12/24/2010
Withdrawal date : 9/30/2019
Number of pages : 134
ICS : 23.040.07 Pipelines and its parts for district heat,23.040.10 Iron and steel pipes,91.140.10 Central heating systems
Technical Committee : 302 - Space heating appliances, ventilation and room air conditioner
- Replaces SR EN 13941:2009
- Replaces SR EN 13941:2009/AC:2010
- Normative reference SR EN ISO 3834-4:2006
- Normative reference SR EN ISO 14731:2007
- Normative reference SR EN ISO 15609-1:2005
- Normative reference SR EN 10216-2:2003
- Normative reference SR EN ISO 15607:2004
- Normative reference SR EN 25817:1993
- Normative reference SR EN ISO 3834-2:2006
- Normative reference SR CR ISO 15608:2002
- Normative reference SR EN ISO 3834-1:2006
- Normative reference SR EN ISO 3834-3:2006
- Normative reference SR EN 10217-1:2002/A1:2005
- Normative reference SR EN 13480-3:2003
- Normative reference SR EN 10217-2:2003/A1:2005
- Normative reference SR EN ISO 9692-2:2000
- Normative reference SR ISO 1000:1995
- Normative reference SR EN 10217-2:2003
- Normative reference SR EN 1714:2000/A2:2004
- Normative reference SR EN 1290:2000/A1:2003
- Normative reference SR EN 1291:2002/A1:2003
- Normative reference SR EN 1435:2001/A2:2004
- Normative reference SR EN 10204:2005
- Normative reference SR EN 1289:2002
- Normative reference SR EN 1290:2000
- Normative reference SR EN 1712:2002/A2:2004
- Normative reference SR EN 488:2004
- Normative reference SR EN 583-1:2001
- Normative reference SR EN 970:1999
- Normative reference SR EN 1291:2002
- Normative reference SR EN 1435:2001
- Normative reference SR EN 1712:2002
- Normative reference SR EN 1714:2000/A1:2003
- Normative reference SR EN 444:1996
- Normative reference SR EN 448:2009
- Normative reference SR EN 473:2008
- Normative reference SR EN 489:2009
- Normative reference SR EN 1289:2002/A1:2003
- Normative reference SR EN 1290:2000/A2:2004
- Normative reference SR EN 571-1:1999
- Normative reference SR EN 1418:2000
- Normative reference SR EN 1714:2000
- Normative reference SR EN 253:2009
- Normative reference SR EN 287-1:2004
- Normative reference SR EN 287-1:2004/A2:2006
- Normative reference SR EN 1291:2002/A2:2004
- Normative reference SR EN 1435:2001/A1:2003
- Normative reference SR EN 1712:2002/A1:2003
- Normative reference SR EN 10217-1:2002
- Normative reference SR EN 13018:2002
- Normative reference SR EN 13018:2002/A1:2004
- Replaced by SR EN 13941-1:2019
- Replaced by SR EN 13941-2:2019
RO