SR EN 50053-3:1997
Requirements for the selection, installation and use of electrostatic spraying equipment for flammable materials. Part 3: Hand-held electrostatic flock spray guns with an energy limit of 0,24 mJ or 5 mJ and their associated apparatus
This European Standard gives requirements for the selection, installation and safe use of hand-held electrostatic flock spray-guns and their associated apparatus complying with EN 50 050 for the following cases when: flock spraying in association with adhesives which can form an explosive atmosphere, then the energy limit of the spray gun shall be 0.24 mJ; flock spraying in association with adhesives which do not form an explosive atmosphere, then the energy limit of the spray gun shall be 0.5 mJ. This European Standard considers only the hazards that are specific to the electrostatic characteristics of the electrostatic spraying process. For other aspects such as classification of hazardous areas (e.g. classification into zones), selection, installation and use of electrical equipment in hazardous areas, health hazards (e.g. toxic and skin effects, electric shock), cleaning of flock spraying areas, fire hazard from external sources, storage and handling of flammable materials, explosion protection systems, national regulations apply. Note: applications of flock spray guns use
You must log in to add this product to favorites.
Status :
Withdrawn
Approval date : 10/11/1996
Publish date : 3/1/1997
Romanian version publish date : 10/11/1996
Withdrawal date : 5/19/2005
Number of pages : 14
ICS : 29.260.20 Electrical apparatus for explosive atmospheres,87.100 Paint coating equipment
Technical Committee : 137 - Electrical apparatus for explosive atmospheres
- Normative reference SR EN 50014:1995
- Normative reference SR EN 60529:1995
- Conflict with SR EN 50050:2004
RO